长距光模块能用短光纤对接测试吗?

首页    技术文档    长距光模块能用短光纤对接测试吗?

问题描述

客户现场有4块80KM长距万兆光模块,测试时使用20M左右短光纤自环接在一台设备上。

查看光模块收发光功率有一块收光高,且有收光高告警。

Ten-GigabitEthernet0/0/26 transceiver information:

  Transceiver Type              : 10G_BASE_ZR_SFP

  Connector Type                : LC

  Wavelength(nm)                : 1550

  Transfer Distance(km)         : 80(SMF)

  Digital Diagnostic Monitoring : YES

  Vendor Name                   : H3C

  Ordering Name                 : SFP-XG-LH80-SM1550-D

 

Ten-GigabitEthernet0/0/28 transceiver information:

  Transceiver Type              : 10G_BASE_ZR_SFP

  Connector Type                : LC

  Wavelength(nm)                : 1550

  Transfer Distance(km)         : 80(SMF)

  Digital Diagnostic Monitoring : YES

  Vendor Name                   : H3C

  Ordering Name                 : SFP-XG-LH80-SM1550-D

 

有收光偏高的告警

Ten-GigabitEthernet0/0/26 transceiver current alarm information:

  RX power high

 

Ten-GigabitEthernet0/0/28 transceiver current alarm information:

  RX power high

 

过程分析

   80KM光模块已经被击穿损坏了,光模块收光已经大于 限,导致接口不能UP。

 

解决方法

40KM以上的长距光模块,如果用短距离的光纤对接,需要加光衰,比如80KM光模块用短光纤对接,要加10dB光衰。 否则很容易把光模块击穿,只要对接十几秒就会造成永久性的物理损坏。

 

本文PDF版本下载

2021年6月22日 15:55
浏览量:0